Macquarie Semiconductor and Technology on behalf of IBM Corporation

Thermo (Fisher) Scientific Orion2

Disclaimer

The images and data contained herein is owned by Macquarie and is intended for use only by potential purchasers of goods shown herein. Except for such permitted usage, no other use of the images and data is permitted and such images and data shall not be exhibited or shown in any websites or social media or for any commercial purposes without Macquarie’s written permission. Therefore, no seller of goods like the goods shown herein has any right or authority to show or exhibit any images or data shown herein.


Asset ID: 210184

Enquire about this product Print spec sheet

Thermo (Fisher) Scientific

Orion2

ESD Simulator / Gun

Support Equipment (Test)

Equipment details:

Date of Manufacture:

Currently Configured for: N/A

Current Equipment Status: Available

Location of Equipment: Essex Junction, United States

Available date: Currently Available

·      Manufacturer: ThermoFisher Scientific and Agilent DSA91304A

·      Model: Orion – 2HR

·      Serial number: 2 W23100P1048AA

·      Spare parts (List as many as possible): None

·      Agilent DSA91304A Scope (Picture Attached at end of document)

·  orion to orion2/Camera upgrade.

·      Original date of purchase or date of mfg: 2/1/2014

·      Condition of item (Excellent, Good, Poor): Excellent

·      Type of product processed through this tool Module

·      Has equipment been cannibalized (Y/N) No

·      Last Date Operated: (MM/DD/YY): 09/24/2020

·      Where is the tool currently located Essex Junction, Vermont

    

Name of Software                    Made By

Scimitar___________                ThermoFisher_________


 Can the software be transferred with the tool? Yes __ No X

 Soft Copy software operating/maintenance manuals may be available


 Stage Information

   Number Of Stage Axis: (X, Y, Z)__X________________________

   Is the Stage Automated or Manual? _Manual________________________________

   Does The Stage Have Vacuum: (Y/N) _Y______________________________                                   

   Is The Stage Heated: (Y/N) ___N____________________________________                                      

   Heat Controller Model: _____N/A____________________________________________

                                                                            

 Facilities Required to Run the Tool (Y / N Or Actual Value):

   Voltage: _120v____                                                 

   Hertz: _60 Hz____                                                  

   Phase: ______

   Power: _15A______                                                

   Vacuum: __Y___                                         

   Air: _____Y_______________                                         

   Gases: ___Y__(Nitrogen Purge)_____________


Standard Feature

 Supports all popular test standards: JEDEC, ESDA, AEC, and CDM2

 Dual camera display permits easy discharge pin alignment during set-up

 Enclosed test area with an antistatic safety cover, allows the area to be flooded with dry air or dry nitrogen to control the humidity during testing

 Event detector confirms ESD discharge and reports when a pin is not stressed

 Automatic waveform capture for calibration or device testing stores Ipeak and min/max values for each captured waveform

 Device under test (DUT) held in place by a vacuum chuck; alignment assured via adjustable fixture

 Software enables user to program test voltages, polarity, and delay time between pulses

 Integrated package outline editor allows creation of any package (including off grid) along with import of package X, Y definitions


Test Area 10.16 cm x 10.16 cm (4 in x 4 in)

Motion System x,y axis: minimum step size 0.001 in with 0.00025-in accuracy (minimum step size 25.4 µm with 6-µm accuracy) z axis: vertical travel to 1.5 in with 0.00025-in accuracy (vertical travel to 38.1 mm with 6-µm accuracy)

Test Voltage Range ±25 V to ±2000 V (±1V steps)

Temperature Range Operating Temperature: +15°C to +30°C (+59°F to +86°F) / Non-operating temperature: +4°C to +60°C (+40°F to +140°F)

Humidity Range 30-60% non-condensing

Dimensions 59 cm (23 in) W x 66 cm (26 in) D x 122 cm (48 in) H

Weight 112 kg (300 lb)

Power Requirement 110-240 VAC, 15A, 50/60 Hz

Customer Supplied Vacuum: ≥ 16” Hg Dry air / nitrogen: 0.25 scfm @ 60 psi max

Product images

The information referenced on this page is accurate to the best of our knowledge. We do not warrant the completeness or accuracy of the information contained herein. Interested parties are encouraged to request inspection to verify equipment condition, configuration, and completeness. Any offer to purchase equipment shall be subject to our standard terms and conditions of sale.


Learn more -

Enquire about this product

I agree to receive further communication from Macquarie Group Limited in accordance with its Privacy Policy, as amended from time to time.

Related products

No results message:
Displayed when filters returns no results.

We couldn't find any items that match your criteria.

Please try a different keyword.

Service unavailable:
Displayed when filter service cannot be reached.