Macquarie Semiconductor and Technology on behalf of Micron Technology Taiwan, Inc. (F11)
The images and data contained herein is owned by Macquarie and is intended for use only by potential purchasers of goods shown herein. Except for such permitted usage, no other use of the images and data is permitted and such images and data shall not be exhibited or shown in any websites or social media or for any commercial purposes without Macquarie’s written permission. Therefore, no seller of goods like the goods shown herein has any right or authority to show or exhibit any images or data shown herein.
Date of Manufacture:
Currently Configured for: 300mm
Current Equipment Status: Available
Asset HDD not included
Location of Equipment: Taoyuan, Taiwan
Available date: Currently Available
Tool config is based on original PO, please verify tool details at tool inspection
OEM: AVIZ
Tool Model: RVP300+
Software Version (include revision #): AVP 2.7.1 V
System Power Rating: 480/120V
Loading Configuration: 4 lots
Process: ATMOXANNL
System, General Specification
Heater element Model: FURNACE,ATM –APL
Process Condition: AP
Maximum Operating Temperature: 1200c
N2 Load Lock: Yes
Wafer Type: 300 SEMI STD-Notch
Qty. of Production Wafers: 120 slots Ladder
Boat Operation: 2 Boat Type
Software Version: AVP 2.7.1 V
System, Furnace
Loading Area Light: White
Force Air Cooling system: installed
O2 Density control: 0-100ppm
Furnace Temperature Controller: SSPC control
System, Wafer/Carrier Handling
Carrier Type: 12" FOUP
Carrier Stage Capacity: 16 FOUP
WTU Type: GenMark
WTU alignment: GenMark
WTU Teaching method: Pre-aligner / dual beam
System, Reactor
Inner Tube Type (AP): Quartz Single
Inner T/C: 12FT/HONEYWELL
Boat Materail/Type: Sic
Pedestal Materail/Type: Quartz
Auto Shutter: installed
System, Power Distribution
Voltage 3phase: 480VAC
Voltage Single-phase: None
Frequency: 60Hz
System, User Interface:
Operation Panel: Keyboard & Screen
Indicator Type: Mouse
Operation software type: Linux
Gas Leak Detector
Gas Leak Detector Materail/Type: GasTech
System, Fixture List, Gas
Vacuum Gauge: one
Missing/Damaged Parts List
None report, please inspect tool to reconfirm
Dry pumps not included
The information referenced on this page is accurate to the best of our knowledge. We do not warrant the completeness or accuracy of the information contained herein. Interested parties are encouraged to request inspection to verify equipment condition, configuration, and completeness. Any offer to purchase equipment shall be subject to our standard terms and conditions of sale.