Macquarie Semiconductor and Technology on behalf of Micron Technology Taiwan, Inc. (F11)
Date of Manufacture: 2010
Currently Configured for: 300mm
Current Equipment Status: Available
Asset HDD not included
Location of Equipment: Taoyuan City, Taiwan
Available date: Currently Available
DIFFUSION 11-3TEL_INDY_ALDOX_01HT TEL INDYPLS ALDZROX
Tool config is based on original PO, please verify tool details at tool inspection
General Specification
Safety Specification:S2-0706/CE
Heater Model: Low-Temp VMM-56-201 4zone/150-600C without RCU
Process Condition: LP
Process Temperature (C):300C
ART Control:None
N2 Load Lock:Yes
Wafer Type: 300mm-Si SEMI STD-Notch
Qty. of Production Wafers: 100wfr
Boat Operation: 2 Boat Type / 2 Boat Operation (B/S)
Software Version (WAVES): Ver. 6.07
Furnace Spec, Furnace
Dewpoint Meter for N2 LL: None
Loading Area Light: White (LED)
RCU Duct Length FNC - RCU: None
Ionizer (maker/model): None
Chemical PreFilter-Acid:None
Chemical PreFilter-Alkali: None
Chemical PreFilter-Hydrocarb: Yes
Chemical PreFilter-Location: Side FFU
Side Maintenance: None
O2 Density Control for N2 LL: Yes
O2 ANALYZER Maker: NGK, Model: SH-304 STANDARD
N2 Boat Shower Wafer Cooling: Yes
Furnace Temperature Controller: Model 560A
Furnace Spec, Wafer/Carrier Handling
Carrier Type: FOUP/25slots, SEMI STD
FOUP Maker/Model: Entegris/Spectra
Carrier Stage Capacity: 18 FOUP
Info Pad A,B: Pin
Info Pad C,D: Pin
Fork Material: Al2O3+PEEK
W/T Type: 1+4 Edge Grip
W/T Type A/T: None
Furnace Spec, Furnace Facilities
Furnace Exhaust Connection Poi: Top Connection
Cooling Water Connection Point:Bottom Connection
RCU DUCT Connection Point:N/A
Gas Spec, Gas Distribution System
IGS Type: IGS 1.125"W-seal rail-mount
IGS Maker:Fujikin
Tubing Bends:Bend (Less than 90deg)
IGS Final Filter:PALL
IGS Regulator: CKD
IGS MFC (Maker/Type):AE / Digital
Water Vapor Generator(WVG):N/A
IGS Press. Transducer: NAGANO
Liquid Source Delivery- 3DMASi: AS-102S-B5/3DMASi 300sccm MCAC./ADVANCED ENERGY
Auto Refill System- 3DMASi:Customer Provided - Bulk 3DMASi delivery system CG325/CG400 GEN II or CG325 GEN II Scumacher-Chemguard
Auto Refill System Provider: Provided by customer
Refill System Tubing interconn: Provided by customer
Ozone Delivery System (Maker/M:"Maker: MKS
Model: AX 8575-29"
Ozone Delivery System: Provider customer 0
Liquid Source Delivery- Zr:Onboard Zr bubbler, ergonomic version
Liquid Source Delivery- X precursor: Onboard Ti bubbler, ergonomic version
Liquid Source Delivery- TMA: Onboard TMA bubbler, ergonomic version
HTR9.1,FLAT,AMPOULE,0DP0: Insulation, Ampoule, Top/9399-0975/MKS
HTR,INS,NBV,MAN KNOB:Insulation, Valve Knob,9599-0665/MKS
HTR2.5,STR6.21,SPEC,1EP0:Insulation, bypass,9525-0060/MKS
HTR2.0,STR5.5,SPEC,1EP0:Insulation, outlet,9520-0839/MKS
HTR2.0,STR5.5,SPEC,1EP0:Insulation, inlet,9520-0840/MKS
Wrap around valve heater (MKS):Valves heated by wrap around heaters supplied by Supplier
Exhaust Specificationbution
Vacuum Gage - Press Ctrl: MKS (Hot) Capacitance Manometer
Vacuum Gage - Press Monitor (1: MKS (Hot) Capacitance Manometer
Vacuum Gage - Pump Monitor:MKS (Hot) Capacitance Manometer
Main Valve: CKD-Hi-Speed VEC
Pump Maker/Model: EDWARDS/IXH1820, OPT: Pump is customer Provided. Ordering Fab must verify pump is purchased for all process chambers.
Pump Provided by: Provided by customer
Abatement System Type: Burning Type Abatement maybe different based on Fab specification.
Abatement System (Maker/Model): Orient service Co.,Ltd / GDO1862-WA Abatement maybe different based on Fab specification.
Abatement System Provider: Customer
N2 Dilution Unit Provided by: Customer
Pump Power: Customer
Pump Control Unit Setting Loca: Power Box Top
Pump-FNC Vacuum Piping Provide: Customer
Reactor Specification
Quartz Provided by: Optional
Quartz Vendor Requirement: Must be Customer qualified supplier
SiC Provided by:N/A
SiC Vendor Requirement: N/A
Liner Tube (AP):N/A
Process Tube (AP, AP+Sub-AP):N/A
Outer/Inner Tube Material: Quartz / Quartz
Inner Tube Type (LP): Cross-flow inner tube Type with narrow slit and wider pitch tab is used (slit size 1007 mm)
Inner T/C: Outer Tube interior wall type (for CVD)
Tube Sealing: O-Ring
Manifold Heater: Yes
Switch Valve for Manifold Cool: Yes
Soft Backfill Injector: Yes
Boat Type: 117 slots Ladder (8mm pitch)
Boat Material: Quartz
Boat Rotation: Yes
Pedestal Type: Quartz
Cap Heater:Yes
Auto Shutter: No Shutter Purge Type
Earthquake Countermeasure: Yes,OPT: Ordering Fab must verify seismic requirements and note any special requirements within the PO.
Power Specification, Power dist System
Voltage 3phase: 480VAC
3phase connection type: Star Connection
Voltage Single-phase: 120VAC
Single-phase connection type: Grounded
Frequency: 60Hz
Wattmeter: None
Control Power UPS provided by: Optional
Control Power UPS type: Fab-wide system
UPS Input/Output Voltage:N/A
Power Specification, Cable Length
Power Cable Input Entrance Loc: Power Box Top
FNC - Power Box:20m
Power Box - RCU: N/A
Power Box - Pump Unit:20m
Power Box -Refill System (if u: 20m
Power Box - WVG CTRL Unit (if: N/A
FNC - WVG CTRL Unit (if used): N/A
Power Box -Scrubber System (if: N/A
Power Box - Ozone Delivery sys: 30m
Power Box - UPS (if used):N/A
Wiring by: Customer
Conduit/Raceways provided by:Customer
Interface Specification, Factory Automation System
Host Communications: Comply with GJG
Equipment Host I/F Connection:Gas Box TOP HSMS (10Base-T/100Base-TX), OPT: Ordering Fab to verify connection point as follows: QTY=1 is Bottom connection, QTY=2 is Top connection, Default = 1, and note any special requirements within the PO.
Ingenio:Yes, OPT: Ordering Fab must specify Ingenio included or not, default is Yes (QTY=1). Set QTY=0 if excluded
Group Controller Connection: Yes
OHT Capability: Yes
AGV Capability: None
RGV Capability: None
PGV Capability: None
Load Port Operation: Upper
PIO I/F Location: FNC Top
PIO Provided by:TEL
PIO Maker/Model: HOKUYO / DMS-HB1-Z series(Head-On)
Carrier ID Reader Writer Type: RF
CIDRW Lower Load Port: Read
CIDRW Upper Load Port: Read
CIDRW FIMS: Read/ Write,OPT: Ordering Fab must verify if Write or Read Write. Write only QTY= 1.Read/Write QTY= 2. Default = 1 . Note any special requirements within the PO.
CIDRW Maker/Model:"Controller is V700-L22-6.
ID READER(HEAD) is V640-HAM11-V2.
ANTENNA is V640-HS61."
CIDRW Provided by: TEL
EEC (Equipment Engineering Cap: FDC(Fault Detection and Classification) "OPT: Ordering Fab must specify if FDC is included or not, Include = QTY=1, Set QTY= 0 if excluded.
Default = 1"
Customized Management Signals: PT / WATER
"INTERFACE PT/WATER: Interface A Option "OPT: Ordering Fab must specify Interface A included or not, Include = QTY=1, Set QTY= 0 if excluded.
Default = 0"
Interface Specification, User Interface
Signal Tower Model: LOUGWB-24-4,OPT: Ordering Fab to verify VAC signal tower as follows: QTY=1 is LOUGWB-24-4, QTY=2 is LOUGWB-24-3, Defualt = 1 and note any special requirements within the PO.
Signal Tower Colors: Red/Yellow/Green/Blue, OPT: Ordering Fab to verify signal tower as follows: QTY=1 is Red/Yellow/Green/Blue , QTY=2 is Red/Yellow/Green, Defualt = 1 and note any special requirements within the PO.
Signal Tower Location: Front
Front Operation Panel: Yes
MMI and Gas FlowChart: Gas Box & Front Operation Panel Installed
Indicator Type: Superset
Operator Switch: Operator Access/Orange (STD)
Pressure Display Unit: MPa / Torr
Cabinet Exh Pressure Display: Pa
Warning Label: English
Other Specification, Unit Location
Furnace (Exh/Box,Gas/Box inclu:Main-Fab
Power Box:Sub-Fab
Pump:Sub-Fab
RCU:N/A
Step Up Transformer:N/A
Step Down Transformer:N/A
Ozone Delivery System:Sub-Fab
WVG Controller:N/A
Auto-Refill System:Sub-Fab
UPS:None
Other Specification, Gas Leak Detector
Condenser:N/A
Gas Leak Detector:YES
Gas Leak Detector Provided By:TEL
Gas Leak Detector Maker:RiKen / GD-K77D-A
Gas Detector Power:Power is provided by Machine
Detected Gas 1 / Location:Optional
Detected Gas 2 / Location:N/A
Detected Gas 3 / Location:N/A
Detected Gas 4 / Location:N/A
Detected Gas 5 / Location:N/A
Detected Gas 6 / Location:N/A
Detected Gas 7 / Location:N/A
Furnace Detection Port:4 points (2 pairs)
Gas Box Detection Port:4 points (2 pairs)
Damage/Missing parts list
Please inspect tool to reconfirm
Dry pumps and customer provided items not included on sales
The information referenced on this page is accurate to the best of our knowledge. We do not warrant the completeness or accuracy of the information contained herein. Interested parties are encouraged to request inspection to verify equipment condition, configuration, and completeness. Any offer to purchase equipment shall be subject to our standard terms and conditions of sale.