Macquarie Semiconductor and Technology on behalf of Micron Technology Taiwan, Inc. (F11)

Tokyo Electron Ltd. (TEL) TELFORMULA ALD High-K

Asset ID: 18420

Print spec sheet

Tokyo Electron Ltd. (TEL)

TELFORMULA ALD High-K

Vertical Furnace

Furnaces/Diffusion Systems

Equipment details:

Date of Manufacture: 2015

Currently Configured for: 300mm

Current Equipment Status: Incoming

Asset HDD not included

Location of Equipment: Taoyuan, Taiwan

Available date: 5/20/2022


2.2- General Specification

Safety Specification - S2-0703 - PartQty1

Heater Model - Mid-Temp. VCM-50-012L - PartQty1

Compatible with Atmoshpheric Process - None - PartQty0

Maximum Operating Temperature (C) - 300 - PartQty1

ART Control - Yes - PartQty1"

N2 Load Lock - Yes - PartQty1"

Wafer Type - 300mm-Si SEMI STD-Notch - PartQty1"

Qty. of Production Wafers - 50 - PartQty1"

Software Version (WAVES) - Ver.2.12 R006 - PartQty1"

Seismic Isolation Configuration - None - PartQty0"


3.1.1- Furnace Spec, Furnace

Dewpoint Meter for N2 LL - None - PartQty0"

Loading Area Light - White (LED) - PartQty1"

RCU Duct Length FNC - RCU - 20m - PartQty0"


Chemical PreFilter-Hydrocarbon - Yes

Chemical PreFilter-Location - FNC Top


3.1.2- Furnace Spec, Wafer/Carrier Handling

Carrier Type - FOUP/25slots, SEMI STD - PartQty1"

FOUP Maker/Model - Entegris / A300 - PartQty1"

Carrier Stage Capacity - 10 - PartQty1"

Info Pad A,B - Pin - PartQty0"

Info Pad C,D - Pin - PartQty0"

Fork Material - Al2O3 - PartQty1"


3.1.3- Furnace Spec, Furnace Facilities

Furnace Exhaust Connection Point - Top Connection - PartQty1"

Cooling Water Connection Point - Bottom Connection - PartQty1"

Electric Fan Exhaust Facility Connection - Not Installed

Air Intake Point - Top - PartQty1"


3.2.1- Gas Spec, Gas Distribution System

IGS Type - IGS 1.5""W-Seal rail-mount - PartQty1"

IGS Maker - Fujikin - PartQty1"

Tubing Bends - Bend (Less than 90deg) - PartQty1"

IGS Final Filter - N2 50L line:Entegris(Ni),

The other N2 line and Process gas line:PALL(SUS) - PartQty1"

IGS Regulator - CKD - PartQty1"

IGS MFC (Maker/Type) - HORIBA STEC / Digital - PartQty1"

IGS MFC for low flow N2 purge when cleaning - HORIBA STEC / SEC-G111 - PartQty1"

IGS Press. Transducer - Nagano - PartQty1"

Liquid Source Vapor System Maker / Model - For TMA HORIBA STEC / LSC-F530

For ZAC(OCTANE) STEC / TL-2013 - PartQty1"

Auto-Refill System- TMA - Air Liquid / CANDI - PartQty1 - Model : CALEN - Japan Air Gases"

Auto Refill System- ZAC - Air Liquid / CANDI - PartQty1 - Model : AQUARIUS - Japan Air Gases"

Ozone Delivery System - Toshiba Mitsubishi / OP-500H-RE1 - PartQty1"

Water Vapor Generator (WVG) - None - PartQty0"


3.2.2- Gas Spec, Gas Facilities

Incoming Gas Connection Point - Bottom Connection - PartQty1"

Gas VENT Connection Point - Bottom Connection - PartQty1"

Exhaust VENT Connection Point - Bottom Connection - PartQty1"

Gas Unit Exh Connection Point - Bottom Connection - PartQty1"


3.3.1- Exhaust Specification button

Vacuum Gage - Press Ctrl - MKS (Hot) Capacitance Manometer - PartQty1"

Vacuum Gage - Press Monitor (133kPa) - MKS (Hot) Capacitance Manometer - PartQty1"

Vacuum Gage - Pump Monitor - MKS (Hot) Capacitance Manometer - PartQty1"

Main Valve - CKD-VEC 3"" - PartQty1"

Pump Maker/Model - EDWARDS / iXH1820 - PartQty1"

Abatement System Type - Burning Type - PartQty1"

Abatement System (Maker/Model) - EDWARDS / Atlas-TPU2 - PartQty1"

Pump Control Unit Setting Location - None - PartQty1"


3.3.1- Exhaust Specification

Exhaust Box - Wide Type (1200mmW) - PartQty1"


3.4.1- Reactor Specification

Cap Type - Quartz - PartQty1"

Cap Heater - Yes - PartQty1"

Cooling Water for Cap Rotation - Yes - PartQty1"

Heat Shield Type - HS Plate - PartQty1"



3.5.1- Power Specification, Power dist System

Voltage 3phase - 480VAC - 200VAC is Ozonizer power - PartQty1"

3phase connection type - Star Connection - PartQty1"

Voltage Single-phase - 200VAC

Frequency - 60Hz


3.5.2- Power Specification, Cable Length

Power Cable Input Entrance Loc - Power Box Top -

FNC - Power Box - 30m

FNC - RCU

Power Box - Pump Unit - 30m

Power Box - Refill System - 30m

Power Box - Ozonizer - 20m - PartQty1"

Ozonizer control rack - Ozonizer - 20m - PartQty1"

Ozonizer control rack - Power Box - 20m - PartQty1"

Ozonizer conrol rack - RCU - 20m - PartQty1"

Ozonizer control rack - Floor Box - 20m - PartQty1"


3.6.1- Interface Specification, Factory Automation System

Host Communications - Comply with GJG - PartQty1"

Equipment Host I/F Connection - Power Box Top

Ingenio - Yes

OHT Capability - Yes - PartQty1"

AGV Capability - None - PartQty1"

RGV Capability - None - PartQty0"

PGV Capability - None - PartQty0"

Load Port Operation - Lower + Upper - PartQty1"

PIO I/F Location - FNC Top - PartQty1"


3.6.1- Interface Specification, Factory

PIO Provided by - TEL - PartQty0"

PIO Maker/Model - Hokuyo / DMS-HB1-Z - PartQty0"

Carrier ID Reader Writer Type - RF - PartQty1"

CIDRW Lower L/P - Read - PartQty1"

CIDRW Upper L/P - Read - PartQty1"

CIDRW FIMS - Read/Write - PartQty1"

CIDRW Maker/Model - HOKUYO DMS-HB1-Z series (Head-On) -

Read/Write QTY= 2. 

CIDRW Provided by - TEL - PartQty0"

CIDRW Tag Orientation - Vertical - PartQty0"

"


3.6.2- Interface Specification, User Interface

Signal Tower Model - LCE Series - PartQty1"

Signal Tower Colors - RED / BLUE / YELLOW GREEN

Signal Tower Location - Front for 10 Stocker (Left) - PartQty1"

Front Operation Panel - Yes - PartQty1"

MMI and Gas FlowChart - Gas Box & Front Operation Panel Installed - PartQty1"

Light Curtain - None - PartQty1"

Indicator Type - Selete - PartQty1"

Operator Switch - Operator Access / White Cover with Orange Light - PartQty1"

Pressure Display Unit - MPa / Torr - PartQty1"

Cabinet Exh Pressure Display - Pa - PartQty1"



3.7.1- Other Specification, Unit Location

Furnace (Exh/Box,Gas/Box inclu - Main-Fab - PartQty1"



3.7.2 - Other Specification, Gas Leak Detector

Gas Leak Detector - YES - PartQty1"


Detected Gas 1 / Location - Detected Gas 1 / Location - Gas box - PartQty1"

Detected Gas 2 / Location - Detected Gas 2 / Location - Gas box - PartQty1"

Detected Gas 3 / Location - Detected Gas 3 / Location - N/A - PartQty0"

Detected Gas 4 / Location - Detected Gas 4 / Location - Gas box - PartQty1"

Detected Gas 5 / Location - Detected Gas 5 / Location - N/A - PartQty0"

Detected Gas 6 / Location - Detected Gas 6 / Location - N/A - PartQty0"

Detected Gas 7 / Location - Detected Gas 7 / Location - N/A - PartQty0"

Gas Box Detection Port - 8 point (4pairs) - OPT: Ordering Fab must verify Port number,

8 Port (4 Pair) = 1, 10 Port (5 Pair ) = 2, Default = 1 note any special requirements within the PO. - PartQty2"


7.0- Attached List

Facility List - Rev.1 - PartQty1"

System layout drawing - 3892-128274-11 - PartQty1 - 3892-128274011"

Electrical System Diagram - Design in progress - PartQty1 - 3892-128213-11"

Cooling Water System Diagram - Design in progress - PartQty1 - 3893-C20822-13"

Conducting (Wire-Way) Work Among Boxes - Design in progress - PartQty1"

Gas System Diagram - 3892-226546-11 - GFC - PartQty1 - 3892-226398-11"

Gas Parts List - 3898-B22513-12 - GPL - PartQty1 - 3898-B22513-12"

Valve Interlock - Design in progress - PartQty1"

Safety Interlock - Rev.1 - PartQty1"

External Input / Output Table - Rev.1 - PartQty1"

Signal Tower Special Sequence - Rev.1 - PartQty1"




Missing/Damaged Parts List

None report, please inspect tool to reconfirm

Enquire about this product

I agree to receive further communication from Macquarie Group Limited in accordance with its Privacy Policy, as amended from time to time.

The information referenced on this page is accurate to the best of our knowledge. We do not warrant the completeness or accuracy of the information contained herein. Interested parties are encouraged to request inspection to verify equipment condition, configuration, and completeness. Any offer to purchase equipment shall be subject to our standard terms and conditions of sale.


Related products

No results message:
Displayed when filters returns no results.

We couldn't find any items that match your criteria.

Please try a different keyword.

Service unavailable:
Displayed when filter service cannot be reached.

Sorry, this service is currently unavailable.

Please try again later.

Get in touch

Have a question for our team?

Ask about our equipment solutions, ranging from Macquarie equipment inventory sales, sourcing programs, surplus disposition options, and direct equipment purchases.

I agree to receive further communication from Macquarie Group Limited in accordance with its Privacy Policy, as amended from time to time.