Macquarie Semiconductor and Technology on behalf of Micron Memory Taiwan Co., Ltd. (F16)
The images and data contained herein is owned by Macquarie and is intended for use only by potential purchasers of goods shown herein. Except for such permitted usage, no other use of the images and data is permitted and such images and data shall not be exhibited or shown in any websites or social media or for any commercial purposes without Macquarie’s written permission. Therefore, no seller of goods like the goods shown herein has any right or authority to show or exhibit any images or data shown herein.
Etch/Ash/Clean - Plasma Processing
Date of Manufacture: Jun 11, 2003
Currently Configured for: 300mm
Current Equipment Status: Available
Asset HDD not included
Location of Equipment: Taichung City, Taiwan
Available date: Currently Available
Software Version | Ver6.75-Rev000-VSTD6.75a | ||
System Power Rating | 200V AC 3-Phase | ||
Loading Configuration | 3 load ports | ||
Vendor Chm Model | Chemicals / Gases Used | ||
Chm/Unit Position 1 | SCCM | Ar ,O2 ,CF4 ,CHF3 ,CH2F2 ,C4F6 ,C4F8 ,CO | |
Chm/Unit Position 2 | SCCM | Ar ,O2 ,CF4 ,CHF3 ,CH2F2 ,C4F6 ,C4F8 ,CO | |
Process Unit: | Model: | Remark | |
Chiller | Daikin UBRPD5B-2T2 | ||
* stopped production | |||
Coolant | Lower:FC3283, Upper:FC40 | ||
Proc Chbr 1,2 | SCCM Oxide; Y203 Coating | ||
ESC type | ESC ASSY,SCCM-OX L | ES3D87-052854-11 | |
Controller: | |||
RF Generator TOP | AGA-50B2 | ||
RF Matcher TOP | AMN-50B2 | ||
RF Generator Bottom | WGA-50E | ||
Matching Controller | WMN-50H6(2MHZ/5KW)(PS3) | ||
MFC/Pressure Unit: | |||
Pressure Monitor | C/M (Process Monitor) : 627BRETDD2P (MKS), 45deg, 30Pa | ||
Pressure Monitor | C/M (Self Check) : 627B11TDC2P (MKS), 45deg, 1330Pa | ||
Pressure Monitor | B.A. Gauge (CM Calibration) : BPG400 (INFICON), 2.0x10-5 ~ 0.1Pa | ||
Pressure Monitor | ATM Switch : 41B13DGA2AA040 (MKS) | ||
Pressure Monitor | Pressure Switch : 51A11TGA2BA010 (MKS), H2/fluoro gas | ||
FOUP Opener: | |||
Loader Module | SELME2112ZS22-AD5 | ||
LOAD PORT | SELOP12F25-30U-14 | ||
DRIVE UNIT | SBX92102928 | ||
READER OPTICAL | ISS-1700-1TELCC | ||
Carrier ID Reader | KEYENCE BL-601 HAC1-SO | ||
Gas System: | |||
Final Pressure Switch | 51A (MKS) | ||
Valve | Primary side(Utility-MFC):Mega mini (FUJIKIN) | ||
Valve | Secondary side(MFC-PC):Mega one (FUJIKIN) | ||
FCS | FCSDN-4WS-798 | ||
Exhuast System: | |||
TMP | FT-3301 | ||
(MITSUBISHI) | |||
TMP Back Pressure Monitor | 51A11TGA2BA003 (MKS) | ||
Final Valve, Heater | Valve; AGD21V-6RM-GWL4 (CKD) | ||
Filter | Filter; CEP-TM_HL-VR-03PB (Toshiba Ceramic) | ||
APC | 10 INCH (250MM) | ||
EMO | Front x1, Rear x3 | ||
Signal Tower | Red/Yellow/Green/ (Upper Left of Front x1 & Upper right section of loader on maintenance side x1) | ||
Cable Length | 12m (Interconnection), 16m (Top RF cables),15m(Btm RF cables) | ||
Coolant | Lower:FC3283, Upper:FC40 |
The information referenced on this page is accurate to the best of our knowledge. We do not warrant the completeness or accuracy of the information contained herein. Interested parties are encouraged to request inspection to verify equipment condition, configuration, and completeness. Any offer to purchase equipment shall be subject to our standard terms and conditions of sale.
Get in touch
Ask about our equipment solutions, ranging from Macquarie equipment inventory sales, sourcing programs, surplus disposition options, and direct equipment purchases.