Macquarie Semiconductor and Technology on behalf of Micron Technology Taiwan, Inc. (F11)
The images and data contained herein is owned by Macquarie and is intended for use only by potential purchasers of goods shown herein. Except for such permitted usage, no other use of the images and data is permitted and such images and data shall not be exhibited or shown in any websites or social media or for any commercial purposes without Macquarie’s written permission. Therefore, no seller of goods like the goods shown herein has any right or authority to show or exhibit any images or data shown herein.
Date of Manufacture:
Currently Configured for: 300mm
Current Equipment Status: Available
Asset HDD not included
Location of Equipment: Taoyuan City, Taiwan
Available date: Currently Available
Process: PEALDOX
Tool config is based on original PO, please verify tool details at tool inspection
Safety Specification: SEMI S2-0709
Heater Model: None
Process Condition: LP
Process Temperature (C): Room Temp
ART Control: None
N2 Load Lock: Yes
Wafer Type: 300mm-Si SEMI STD-Notch
Qty. of Production Wafers: 100wfr
Boat Operation: 1 Boat Type
Software Version (WAVES): Ver. 6.08
Seismic Isolation Configuration: None
Dewpoint Meter for N2 LL: None
Loading Area Light: White (LED)
RCU Duct Length FNC - RCU: N/A
Ionizer (maker/model): None
Chemical PreFilter-Acid: None
Chemical PreFilter-Alkali: None
Chemical PreFilter-Hydrocarb: Yes
Chemical PreFilter-Location: Side FFU
Side Maintenance: None
O2 Density Control for N2 LL: Yes
"O2 ANALYZER: Maker: NGK, Model: SH-304 STANDARD
(New CIP item: Remove O2 detector and FIMS sampling function)"
N2 Boat Shower Wafer Cooling: None
Furnace Temperature Controller: None
Carrier Type: FOUP/25slots, SEMI STD
FOUP Maker/Model: Entegris/A300
Carrier Stage Capacity: 18 FOUP
Info Pad A,B: Pin
Info Pad C,D: Pin
Fork Material: Al2O3+PEEK
W/T Type: 1+4 Edge Grip
W/T Type A/T: Yes
Furnace Exhaust Connection Point: Top Connection
Cooling Water Connection Point: None
RCU DUCT Connection Point: N/A
IGS Type: IGS 1.125"W-seal rail-mount
IGS Maker: Fujikin
Tubing Bends: Bend(Less than 90deg.)
IGS Final Filter: Entegris
IGS Regulator: CKD
IGS MFC (Maker/Type): HORIBA STEC/Digital
Water Vapor Generator(WVG): N/A
IGS Press. Transducer: Nagano
Liquid Source Delivery- LTO520: HORIBA STEC / LSC-F550 Series
Auto Refill System- LTO520: IMI: Schumacher CGII-300T
Auto Refill System Provider: Provided by customer
Refill System Tubing interconn: Provided by customer
Ozone Delivery System: None
Ozone Delivery System Provider: N/A
Incoming Gas Connection Point: Bottom Connection
Exhaust VENT Connection Point: Bottom Connection
Gas Unit Exh Connection Point: Bottom Connection
Vacuum Gage - Press Ctrl: MKS (Hot) Capacitance Manometer
Vacuum Gage - Press Monitor (133kPa): MKS (Hot) Capacitance Manometer
Vacuum Gage - Pump Monitor: MKS (Hot) Capacitance Manometer
Main Valve: CKD-VEC
Pump Maker/Model: Edward 3030T
Pump Provided by: Provided by customer
Abatement System Type: Burning Type
Abatement System (Maker/Model): EBARA / VIPS
Abatement System Provider: Customer
N2 Dilution Unit Provided by: No NDU
Pump Power: Customer's Facility Provided
Pump Control Unit Setting Location: None
Pump-FNC Vacuum Piping Provide: Customer's Facility Provided
Exhaust Pressure Control (AP): N/A
Exhaust Pressure Controller (AP): N/A
Vacuum Exhaust System: 3inch Pipe
Trap: None
Vacuum Pressure Controller: CKD-VEC
Burn Out Unit: None
Condenser: N/A
Quartz Material Requirement: Electric Fused
Quartz Provided by: Costumer
Quartz Vendor Requirement: None
SiC Provided by: N/A
SiC Vendor Requirement: N/A
Process tube: Quartz IRad Tube
Inner T/C: None
Tube Sealing: The sealing material for CAP is Q-ring(DU353)
Soft Backfill Injector: None
Boat Type: 117 slots Ladder (8mm pitch)
Boat Material: Quartz
Boat Rotation: Yes
Pedestal Type: Quartz
Cap Heater: None
Auto Shutter: Shutter Purge Type
Earthquake Countermeasure: Yes
Voltage 3phase: 208VAC
3phase connection type: Star Connection
Voltage Single-phase: None
Single-phase connection type: N/A
Frequency: 60Hz
Wattmeter: None
RF Power Unit / Max Rating Power: 0.5kW (Max)
RF Power Unit / Max Operable Power: 0.5kW (Max)
RF Power Unit / Frequency: 13.56MHz
Control Power UPS provided by: Customer
Control Power UPS type: Fab-wide system
UPS Input/Output Voltage: N/A
Power Cable Input Entrance Loc: Furnace Unit Bottom
FNC - Pump: 30m
FNC -Refill System : 30m
FNC - UPS (if used): N/A
Wiring by: Customer
Conduit/Raceways provided by: Customer
Host Communications: Comply with GJG
Equipment Host I/F Connection: Gas Box TOP HSMS (10Base-T/100Base-TX)
Ingenio: Yes
Group Controller Connection: Yes
OHT Capability: Yes
AGV Capability: None
RGV Capability: None
PGV Capability: None
Load Port Operation: Upper
PIO I/F Location: FNC Top
PIO Provided by: TEL
PIO Maker/Model: Hokuyo / DMS-HB1-Z
Carrier ID Reader Writer Type: RF
CIDRW Lower Load Port: Read
CIDRW Upper Load Port: Read
CIDRW FIMS: Read/Write
CIDRW Maker/Model: Maker:Omron amp unit: V640-HAM11-V3, CID RW Controller: V700-L22
CIDRW Provided by: TEL
EEC (Equipment Engineering Capability): None
"Customized Management Signals: (PT/WATER and blow two item will be added)
1.Valve voltage of MFC is output to Waves and Ingenio
The object of MFC:NX,NY,N1,N2,N3,N4,O1,XF1,NXF1,GG1
2.The differential pressure of N2 L/L will be asked to get SVID and show in waves."
"Signal Tower Model: Front operation panel top:LOUGWB-24-3 LOUGWB-24-4
Gas box rear:LOULWB-24-3 "
Signal Tower Colors: Red/Blue/Yellow/Green
Signal Tower Location: Front
Front Operation Panel: Yes
MMI and Gas FlowChart: Gas Box & Front Operation Panel Installed
Indicator Type: TEL provided new indicator type
Operator Switch: Operator Access/White Cover with Orange Light
Pressure Display Unit: MPa/Torr
Cabinet Exh Pressure Display: Pa
Warning Label: Traditional Chinese/English (English will be first priority where can stick only label)
Furnace (Exh/Box,Gas/Box inclu: Main-Fab
Power Box: N/A
Pump: Sub-Fab
RCU: N/A
Step Up Transformer: N/A
Step Down Transformer: N/A
Ozone Delivery System: N/A
WVG Controller: N/A
Auto-Refill System: Sub-Fab
UPS: None
Gas Leak Detector: YES
Gas Leak Detector Provided By: TEL
Gas Leak Detector Maker: Optional Riken
Gas Detector Power: Tool provided
Detected Gas 1 / Location: HF/Gas box
Detected Gas 2 / Location: LTO520/Gas box
Detected Gas 3 / Location: LTO520/Scavenger exhaust
Detected Gas 4 / Location: N/A
Detected Gas 5 / Location: N/A
Detected Gas 6 / Location: N/A
Detected Gas 7 / Location: N/A
Furnace Detection Port: 2 points (1 pair)
Gas Box Detection Port: 4 points (2 pairs)
Damage/Missing parts list
Please inspect tool to reconfirm
Dry pumps and customer provided items not included on sales
The information referenced on this page is accurate to the best of our knowledge. We do not warrant the completeness or accuracy of the information contained herein. Interested parties are encouraged to request inspection to verify equipment condition, configuration, and completeness. Any offer to purchase equipment shall be subject to our standard terms and conditions of sale.